Measures heat flow into and out of a material to determine melting point, crystallization, and thermal transitions.
Applicable Industries
Our engineering team typically responds within 24 hours.
Differential Scanning Calorimeter (DSC) is one of the most accurate DSC series products launched by the company. The sensor is made of imported material E-pair, which has high accuracy, high sensitivity and good repeatability. The signal acquisition circuit has shielding protection, strong anti-interference, and extremely high baseline stability and repeatability.
Differential Scanning Calorimeter (DSC) can be used to test glass transition temperature, phase transition temperature, melting point, enthalpy value, curing temperature, product stability, oxidation induction period, etc. It is competent in the research of pipes, polymers, chemicals, food, medical treatment and many other fields, and its products serve universities, enterprises, third-party measurement and quality inspection units, with a wide range of applications to meet the testing needs of various industries.
| Temperature Range | Room temperature ~ 600℃ |
|---|---|
| Temperature Resolution | 0.01℃ |
| Temperature Fluctuation | ±0.1℃ |
| Temperature Repeatability | ±0.1℃ |
| Heating Rate | 0.1~100℃/min |
| Incubation Time | Program setting ≤24h |
| Temperature Control | Heating up, constant temperature, cooling down (Full automatic program control) |
| DSC Range | 0~±600mW |
| DSC Resolution | 0.01uW |
| DSC Sensitivity | 0.01mW |
| Working Power Supply | AC220V/50Hz Or customized |
| Atmosphere Control Gas | Nitrogen, Oxygen (Program setting/automatic switching) |
| Gas Flow | 0–200mL/min |
| Gas Pressure | ≤0.5MPa |
| Display Mode | 24bit color, 7-inch LCD touch screen display |
| Data Interface | Standard USB interface |
| Parameter Standard | Equipped with reference materials (indium, tin), The user can correct the temperature by himself |
| Temperature Monitoring | The instrument has multiple sets of thermocouples. Temperature of a group of measured samples, one group to measure furnace temperature, one group measures the internal ambient temperature |
| Cooling Device | Air cooling device (Optional semiconductor <-40~550℃>, Liquid nitrogen refrigeration <-150~550℃>) |
The Differential Scanning Calorimeter (DSC) is widely used for thermal analysis of polymer and plastic materials. It can accurately determine the glass transition temperature (Tg), melting point, phase transition behavior, oxidation induction period, and product stability, making it suitable for quality control, product development, and material research.
The instrument is suitable for thermal stability analysis, enthalpy measurement, phase transition studies, and material characterization of various chemical products, providing reliable data for research and industrial applications.
It can be used for product quality analysis, thermal behavior evaluation, and stability studies of food materials, helping manufacturers improve product quality and consistency.
The Differential Scanning Calorimeter (DSC) supports material research, thermal characterization, and product quality inspection for medical materials and related applications, ensuring accurate and repeatable thermal analysis results.